Описание

  • Guard locking for protection of persons or processes
  • Locking module MGB2 for connection to a bus module MBM
  • Locking with monitored guard locking
  • Category 4/PL e for the evaluation of all safety functions
  • Two blanking covers (without submodules)
  • Adjustable door hinge, factory setting: right
  • Unicode
  • Compatible with all Modular devices
Guard locking type
MGB2-L2...Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. (Open-circuit current principle)
Door hinge On the locking modules, the door hinge can be changed from right to left and vice versa at any time with little effort. Dimension drawing Dimension drawing MGB2 Modular: an overview Multifunctional door locking systems Dimension drawingDimension drawing Technical dataApprovals Mechanical values and environment
Installation orientation Door hinge DIN right
AC-MC-00-0-B-156718 (Order no. 156718) Mechanical values and environment
Material Fiber glass reinforced plastic
Weight
Net 0,05 kg
Ambient temperature -25 ... 90 °C
Connection 1
Degree of protection IP65
Connection 2x M4 screws
Electrical connection ratings
Degree of contamination according to EN 60664-1 3
Other
Additional feature
Incl. fixing screws
Incl. seal
Color Black
Locking module MGB2-L2-MLI-U-Y0000-BJ-156392 (Order no. 156392) Mechanical values and environment
Housing material Fiber glass reinforced plastic, die-cast zinc, nickel plated
Weight
Net 1,0 kg
Ambient temperature
At UB = 24V DC -25 ... 55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Reaction time See operating instructions for bus module MBM-...
Switching frequency 0,25 Hz
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.350 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 1,5 kV
EMC protection requirements EMC directive 2014/30/EU
Degree of contamination (external, according to EN 60947-1) 3
Safety class III
Transponder coding Unicode
Power supply MLI
Operating voltage DC
MLI 24 V DC -25% ... 15%
Auxiliary voltage DC
MLI 24 V DC -25% ... 15%
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 7.212 x 109
Diagnostic Coverage (DC) 99
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
Submodule MSM-1-N-AA-000-A4-126372 (Order no. 126372) Mechanical values and environment
Material Fiber glass reinforced plastic
Weight
Net 0,05 kg
Ambient temperature
At UB = 24V DC -25 ... 55 °C
Resilience to vibration In acc. with EN 60947-5-3
Installation orientation Any
Submodule MSM-1-N-AA-000-A4-126372 (Order no. 126372) Mechanical values and environment
Material Fiber glass reinforced plastic
Weight
Net 0,05 kg
Ambient temperature
At UB = 24V DC -25 ... 55 °C
Resilience to vibration In acc. with EN 60947-5-3
Installation orientation Any
Module connector AC-MC-SB-M-A-157024 (Order no. 157024) Mechanical values and environment
Weight
Net 0,05 kg
Ambient temperature -25 ... 90 °C
Connection 1
Degree of protection IP65
Insertion cycles 100
Connection 2x M4 screws
Connection type Plug
Number of pins 5
Plug housing material Plastic
Connection 2
Degree of protection IP65
Type specification M12 EN 61076-2-101 / A-coded
Plug lock material Die-cast zinc, nickel-plated
Insertion cycles 100
Connection Screw terminal
Connection type Plug
Number of pins 5
Plug housing material Plastic, die-cast zinc, nickel plated
Electrical connection ratings
Rated voltage 30 V
Nominal current
At 40°C 4 A
Rated voltage 36 V
Degree of contamination according to EN 60664-1 3
Connecting cable
MLI 5-pin, M12x1
Components 156718 AC-MC-00-0-B-156718
  • Cover for unused connections
  • incl. fixing screws
  • incl. seal
156392 Locking module MGB2-L2-MLI-U-Y0000-BJ-156392
  • Guard locking for protection of persons or processes
  • Locking module MGB2 for connection to a bus module MBM
  • Locking with monitored guard locking
  • Category 4/PL e for the evaluation of all safety functions
  • Open version (without submodules)
  • Adjustable door hinge
  • Unicode
  • Compatible with all Modular devices
126372 Submodule MSM-1-N-AA-000-A4-126372
  • Function expansion for modules MGB2 and MCM
  • Connection type: N
  • Blanking cover
126372 Submodule MSM-1-N-AA-000-A4-126372
  • Function expansion for modules MGB2 and MCM
  • Connection type: N
  • Blanking cover
157024 Module connector AC-MC-SB-M-A-157024
  • Module plug connector MLI (M12), straight
  • Number of pins: 5-pin , plug
''