Описание

  • Read head with guard locking without guard lock monitoring
  • Locking force 650 N
  • With permanent magnet 30 N
  • Up to category 4 according to EN ISO 13849-1
  • Two safety screws M5x16 included
Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off.
Material
Read head Plastic (PPS)
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Weight
Net 0,4 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Switching frequency
Read head See operating instructions for the related evaluation unit
Solenoid max.1 Hz
Connection
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
X3, read head Plug connector M8x1, 3-pin male (with snap-action / screw terminal)
Cable length max.25 m
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 650 N
Adhesive force
by permanent magnet 30 N
Electrical connection ratings
Operating voltage DC
UCM 24 V DC -15% ... 10%
Current consumption
UB 100 mA
Power consumption 2,5 W
Solenoid duty cycle 100 %
Work area
Switching hysteresis 0,7 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao min.2 mm
Center offset -2,5 ... +2,5 mm
''